XSW-DT2B1V0 Display Controller

NegotiableUpdate on 01/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
XSW-DT2B1V0 display controller XSW-CHT2A1B1V1 display controller power supply 24VDC, XSW series single channel thermal instrument classification: XSW-A XSW-B XSW-C XSW-D XSW-E
Product Details

XSW-DT2B1V0 Display Controller 

Double four digit digital display (main display+second display), where the second display can display information such as engineering units. Full signal input, selected through settings.

Optional 1-4 point alarm output. This includes five basic alarm modes: upper limit of measurement value, lower limit of measurement value, upper limit of deviation, lower limit of deviation, and deviation value, as well as five standby alarm modes corresponding to the five basic alarm modes (standby alarm mode: refers to the situation where the instrument does not alarm even when it is in the alarm area when powered on, and establishes a standby condition when the measurement value enters the non alarm area, and then alarms normally thereafter).

XSW-CHT2A1B1V1N Single Channel Display Controller

XSW-CHT2A1B1V1 Display Controller

0.2 level accuracy, measurement and control speed of 10 times per second, display range -1999~9999.

XSW-DT2B1V0 Display Controller 

Thermal meters refer to instruments commonly used for measuring and controlling thermal quantities. Common thermal quantities generally include temperature, humidity, pressure, liquid level, material level, and composition. The single channel thermal meter includes 7 series of products, with the main differences in measurement accuracy, measurement and control speed, and optional functions.

CH6 is a universal economy type. Standard configuration includes 2-point alarm output and transmitter power supply, with optional transmission output. Applications that meet the accuracy requirement of 0.5 level for display, alarm, and transmission. The XST series is a standard type with an accuracy level of 0. z, meeting the requirements of the vast majority of applications.

The difference between the XSW series and XST is that the input signal is input, which can be selected through settings.

The XSE and XSE6 series are high-precision models. XSE6 measurement and control speed can be set, balancing the requirements of accuracy and speed.

The XSE6 thermistor adopts a 4-wire system, and the cold end compensation element of the thermocouple is external, thus achieving higher system measurement accuracy.

The characteristic of the XS series is its fast speed, which can reach a measurement speed of 300 times per second. To ensure timely transmission of measurement data to the upper computer, communication can be set to active sending mode. The XSI-AHT2.1B10O temperature controller XSBT is a two-wire circuit display that does not require power supply and can be connected in series in a 4-20mA circuit to achieve data display.

CHB (E) series, KSE5 series, XsSs2 series, KSBEZE series, CTBe6 f) series, K5T -=series, DOY206o series, CHe series, xSY series, xs5x series, x.S2V series, Jumping T series, Xs series, X.s2 series, ED4 series, XSD&L series, Soc series, Z.SLc series, XSL_ series, KsS.8 series, KSL.E series, XSR21R series, XS.25R series, XSRE5O series, K3 Jumping E5ON series, ZSE50B series, X590 series, E8.5 series, x3C6 series, xS column, XSA Series, XSaE series, XSANV series, CBJ series, xSJ series, XSJB series, ZS.2EA/EB/RC series, xS.2Z3C、 Series, X3.32C series, ES series, xSJZL series, XS.2S0c series, sSc series, XsE series, XSM series, XSY series, xSV series, Ds series, Js series, XSD series, DP series, PR printer, JR485 series, XSB-IT series, MMB3.0 series.

10 segment line correction function.

Peak and valley value acquisition function. Optional communication and transmission.

XSW-CHT2A1B1V1VON Display Controller

XSW-CHT2A1B1V1N Display Controller XSW-BT4B1V1 Display Controller XSW-BT3B1VO Display Controller XSW-BT2B1VO Display Controller XSW-BT1B1VO Display Controller

(1) The current input wiring has been changed from terminal BC to terminal AC, while other input signals remain unchanged. In order to prevent users who are used to wiring old products from misconnecting, the new version of the product will add a prompt label for current input wiring at the product terminal when it leaves the factory.

Input wiring diagram

(2) Add RS485 communication options.

(3) Improved the accuracy and stability of the product.

Detailed introduction

• 0.5 level accuracy, measurement and control speed of 5 times per second. 4-digit LED display.

Standard 2-point alarm output. Alarm mode and alarm sensitivity can be set.

Transmission, communication, and external supply can only be chosen from three options.

Universal input, selected through settings.