electronic weighbridgeInstallation is an important step, and even the best electronic weighing scale can result in inaccurate weighing if installed and adjusted improperly. At the same time, the installation of electronic weighing scales is also a region that hones the combat effectiveness of electronic weighing scale companies. Companies with combat effectiveness usually have skilled installation personnel, and the installed electronic weighing scales weigh accurately. However, many small companies lack work experience, and the process of installing electronic weighing scales is often difficult and not worth the loss. Below, the editor will introduce it to everyone.

1. Before installation, it is necessary to have sufficient communication and exchange with the construction unit to ensure that the pit foundation is properly made. In many cases, due to poor communication and exchange, the deep foundation pit cannot be made properly, resulting in the inability to install electronic weighing scales. We have encountered such situations before, so it is crucial to have sufficient communication and exchange with customers and construction units in advance.
Before installation, it is necessary to check whether the sensor installation location is at the same level. If the foundation is not leveled, it will not only cause inaccurate weighing, but also easily damage the electronic weighing scale. The height to width ratio deviation of each sensor installation location cannot exceed 3mm.
3. Check each component according to the waybill and verify if the components are detailed.
4. When installing the sensor, tighten the connecting anchor bolts with a torque of 1470 n. m.
5. Sensor power cord. The power plug. Shielded cable. Wire connectors must be connected to the junction box according to the specified location. The data signal is summarized in the junction box and then connected to the dashboard. The switch power supply of the dashboard power supply system requires a communication AC adjustable voltage regulator power supply. The dashboard needs to have excellent grounding devices.
6. After the installation of the components, it is necessary to carefully check whether each sensor is at the same level and whether the deviation of each angle of the electronic weighing scale is within the allowable standard.